25 research outputs found

    Airborne hyperspectral discrimination of tree species with different ages using discrete wavelet transform

    Get PDF
    In this article, the capability of discrete wavelet transform (DWT) to discriminate tree species with different ages using airborne hyperspectral remote sensing is investigated. The performance of DWT is compared against commonly used traditional methods, i.e. original reflectance and first and second derivatives. The hyperspectral data are obtained from Thetford forest of the UK, which contains Corsican and Scots pines with different ages and broadleaved tree species. The discrimination is performed by employing three different spectral measurement techniques (SMTs) including Spectral Angle Mapper (SAM), Spectral Information Divergence (SID), and a combination of SAM and SID. Five different mother wavelets with a total of 50 different orders are tested. The wavelet detail coefficient (CD) from each decomposition level and combination of all CDs plus the approximation coefficient from the final decomposition level (C-All) are extracted from each mother wavelet. The results show the superiority of DWT against the reflectance and derivatives for all the three SMTs. In DWT, C-All provided the highest discrimination accuracy compared to other coefficients. An over- all accuracy difference of about 20 – 30% is observed between the finest coefficient and C-All. Amongst the SMTs, SID provided the highest accuracy, while SAM showed the lowest accuracy. Using DWT in combination with SID, an overall accuracy up to around 71.4% is obtained, which is around 13.5%, 14.7%, and 27% higher than the accuracies achieved with reflectance and first and second derivatives, respectively

    Measurement of a wide-range of X-ray doses using specialty doped silica fibres

    Get PDF
    Using six types of tailor-made doped optical fibres, we carry out thermoluminescent (TL) studies of X-rays, investigating the TL yield for doses from 20 mGy through to 50 Gy. Dosimetric parameters were investigated for nominal 8 wt% Ge doped fibres that in two cases were co-doped, using B in one case and Br in the other. A comparative measurement of surface analysis has also been made for non-annealed and annealed capillary fibres, use being made of X-ray Photoelectron Spectroscopy (XPS) analysis. Comparison was made with the conventional TL phosphor LiF in the form of the proprietary product TLD-100, including dose response and glow curves investigated for X-rays generated at 60 kVp over a dose range from 2 cGy to 50 Gy. The energy response of the fibres was also performed for X-rays generated at peak accelerating potentials of 80 kVp, 140 kVp, 250 kVp and 6 MV photons for an absorbed dose of 2 Gy. Present results show the samples to be suitable for use as TL dosimeters, with good linearity of response and a simple glow curve (simple trap) distribution. It has been established that the TL performance of an irradiated fibre is not only influenced by radiation parameters such as energy, dose-rate and total dose but also the type of fibre

    Big Data Analytics for Earth Sciences: the EarthServer approach

    Get PDF
    Big Data Analytics is an emerging field since massive storage and computing capabilities have been made available by advanced e-infrastructures. Earth and Environmental sciences are likely to benefit from Big Data Analytics techniques supporting the processing of the large number of Earth Observation datasets currently acquired and generated through observations and simulations. However, Earth Science data and applications present specificities in terms of relevance of the geospatial information, wide heterogeneity of data models and formats, and complexity of processing. Therefore, Big Earth Data Analytics requires specifically tailored techniques and tools. The EarthServer Big Earth Data Analytics engine offers a solution for coverage-type datasets, built around a high performance array database technology, and the adoption and enhancement of standards for service interaction (OGC WCS and WCPS). The EarthServer solution, led by the collection of requirements from scientific communities and international initiatives, provides a holistic approach that ranges from query languages and scalability up to mobile access and visualization. The result is demonstrated and validated through the development of lighthouse applications in the Marine, Geology, Atmospheric, Planetary and Cryospheric science domains

    Recent advances in silica glass optical fiber for dosimetry applications

    Get PDF
    In this paper, we review the highly promising silica glass, fabricated as doped and undoped optical fiber for intended use in radiation dosimetry. The dosimetry techniques reviewed here, underpinned by intrinsic and extrinsic defects in silica glass, focus on Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radioluminescence (RL), with occasional references to the much more established Radiation Induced Attenuation (RIA). The other focus in this review is on the various materials that have been reported earlier as dopants and modifiers used in silica glass optical fiber radiation dosimeters. This article also elaborates on recently reported optical fiber structures, namely, cylindrical fibers, photonic crystal fibers and flat fibers, as well as dimensions and shapes used for optimization of dosimeter performance. The various types of optical fiber radiation dosimeters are subsequently reviewed for various applications ranging from medical dosimetry such as in external beam radiotherapy, brachytherapy and diagnostic imaging, as well as in industrial processing and space dosimetry covering a dynamic dose range from μGy to kGy. Investigated dosimetric characteristics include reproducibility, fading, dose response, reciprocity between luminescence yield to dose-rate and energy dependence. The review is completed by a brief discussion on limitations and future developments in optical fiber radiation dosimetry

    Characterization of Transient Response in Fiber Grating Fabry–Perot Lasers

    No full text

    Characterization of Turn-On Time Delay in a Fiber Grating Fabry–Perot Lasers

    No full text

    Business process transformation in financial market: A hybrid BPM‐ELECTRE TRI for redesigning a securities company in the Iranian stock market

    No full text
    The author's final peer reviewed version can be found by following the URI link. The Publisher's final version can be found by following the DOI link.Purpose Business Process Management is a systematic way to design, implement and manage business critical processes at different organizational levels to ensure business sustainability. In this paper, we conduct a business process re‐engineering exercise for KBK Securities Co., a small size security company operating in Iranian stock and mercantile market. The company suffered from in‐efficiencies and poor and delayed decision‐making due to poor visibility and complexity with business critical processes. Design We employed a semi‐quantitative approach using ELECTRE TRI decision‐making method to identify the business critical processes. Through document analysis, we identified 103 financial and stock market processes to streamlining purposes. We use Multi‐Attribute Utility Theory (MAUT) and ELECTRE TRI methods for first, arriving to a consensus for the imprecise information elicited from a group of departmental managers, and second making a decision‐making to determine the 32 business critical processes out of 103, and third clustering these processes for business process re‐engineering. We make significant contribution in theory by employing a multi criterion decision‐making (MCDM) in the financial sector in the context of a developing economy like Iran. Originality We provide a structured framework along with an off the shelf software tool for practitioners to implement this approach to rationalize the number of processes and subsequently to improve the business critical processes to enhance financial performance in the stock market. Findings Our findings suggest that company can cut down approximately 68% waste by reducing its business critical processes and spend their available time and resources in growing the business

    High sensitivity flat SiO fibres for medical dosimetry

    No full text
    We describe investigation of a novel undoped flat fibre fabricated for medical radiation dosimetry. Using high energy X-ray beams generated at a potential of 6MV, comparison has been made of the TL yield of silica flat fibres, TLD-100 chips and Ge-doped silica fibres. The flat fibres provide competitive TL yield to that of TLD-100 chips, being some 100 times that of the Ge-doped fibres. Pt-coated flat fibres have then been used to increase photoelectron production and hence local dose deposition, obtaining significant increase in dose sensitivity over that of undoped flat fibres. Using 250kVp X-ray beams, the TL yield reveals a progressive linear increase in dose for Pt thicknesses from 20nm up to 80nm. The dose enhancement factor (DEF) of (0.0150±0.0003)nm Pt is comparable to that obtained using gold, agreeing at the 1% level with the value expected on the basis of photoelectron generation. Finally, X-ray photoelectron spectroscopy (XPS) has been employed to characterize the surface oxidation state of the fibre medium. The charge state of Si2p was found to lie on 103.86eV of binding energy and the atomic percentage obtained from the XPS analysis is 22.41%. © 2014 Elsevier Ltd

    Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    No full text
    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient’s eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose
    corecore